Skip to content

Multi-node without Kubernetes

Modelship has two well-worn rungs: one container running its own Ray head, or full Kubernetes via the Helm chart. This page covers the rung in between — a handful of plain docker run VMs, no cluster orchestrator, joined into one Ray cluster via --address/--token.

If you're choosing a topology from scratch: single container is right until you need more GPUs than one box has; this page is right for a few-VM fleet you manage by hand; Kubernetes is right once you want autoscaling, self-healing pod scheduling, or you already run k8s for everything else.

Non-negotiables

  • Private network only. Ray's cluster-internal RPC (GCS, raylet, object manager) is not designed to be internet-facing — RAY_AUTH_MODE=token authenticates it, but the token travels as plaintext and never expires, so it is not encryption and not a substitute for network isolation. Put every node on a private VPC/VLAN; for cross-provider fleets, a VPN (WireGuard is a common, simple choice) that makes the VMs behave like they're on one LAN. Exposing Ray ports to the public internet is exactly the ShadowRay / CVE-2023-48022 exposure class — mass-exploited GPU clusters, arbitrary code execution via the jobs API.
  • --network=host on every node. Ray advertises the node's own IP and opens a wide dynamic port range; bridge networking is a well-documented source of pain with it. Host networking on an already-private network sidesteps that entirely.
  • Pin every node to the identical release version. Floating tags (:latest, :latest-cuda, :latest-cpu) are single-node only — Ray refuses to form a cluster across mismatched versions. Multi-node means every docker run, on every VM, uses the same :X.Y.Z release — the thin/-cuda/-cpu suffix can differ per node's role, but the version number can't.

Quick start: a two-VM cluster

VM A becomes the head (control plane + gateway; no models scheduled there) and uses the thin (bare-tag) image — no torch/vllm needed for that role. VM B joins it as a GPU worker on the -cuda tag. Every node in a multi-node cluster must share the same version, even across variants — pin all of them to the identical X.Y.Z release.

VM A — head, with cluster auth enabled:

docker run -d --network=host --shm-size=8g \
  -v ./models.yaml:/modelship/config/models.yaml \
  -v ./models-cache:/.cache \
  -e MSHIP_STATE_STORE=redis://your-redis-host:6379/0 \
  ghcr.io/alez007/modelship:0.6.5 \
  --ray-auth=token --ray-port=6380

--ray-port defaults to 6380 already (deliberately not Ray's own 6379 default, which collides with the Redis state store above under host networking) — passed explicitly here only for clarity.

Retrieve the token a joiner needs (Ray generates and owns it; modelship never writes or logs it):

docker exec <head-container> cat ~/.ray/auth_token

VM B — joins VM A as a GPU worker:

docker run -d --network=host --shm-size=8g --gpus all \
  -v ./models-cache:/.cache \
  ghcr.io/alez007/modelship:0.6.5-cuda \
  --address=<vm-a-private-ip>:6380 --token=<token-from-above>

No --config is needed on the joiner — it contributes compute and reconciles the cluster to whatever the head's effective config already wants deployed (the same self-heal mechanism --reconcile uses after a cluster loss). Pass --config/--reconcile on a joiner only if you also want it to change the desired model set, not just add capacity.

--token only means anything if the head runs --ray-auth=token. Joining with a token against a head that has auth disabled doesn't fail — the joiner's own node starts demanding bearer tokens on inbound RPC while the head never sends them, so the join looks like it succeeded and then cluster↔worker traffic fails confusingly. There's no reliable way to detect this from the joining side; treat "auth enabled on the head" and "token passed on the join" as a matched pair you set deliberately, not independent toggles.

Ports and firewall

Port What Configurable via
8000 Gateway HTTP API (ProxyLocation.EveryNode — every node with ≥1 replica runs a proxy) --openai-api-port
8079 Prometheus metrics RAY_METRICS_EXPORT_PORT (own-head); left dynamic on a joiner by design, since the head's own service-discovery file picks it up automatically
8265 Ray dashboard (head only) --dashboard-port (bind host separately via MSHIP_RAY_DASHBOARD, default 127.0.0.1 — keep it there unless you have a specific reason to expose it)
GCS (head control plane) what a joiner's --address points at --ray-port (default 6380)
10002–19999 + node/object manager Ray's dynamic worker range not configurable; open the range between fleet nodes

Open cluster ports only between fleet nodes on the private network. From outside that network, only 8000 (the gateway) should be reachable at all, ideally behind TLS termination.

Per-node weight cache

Each node downloads its own copy of whatever models get scheduled onto it — built-in loaders resolve and validate model references on the driver (auth failures, missing repos, bad selectors all surface immediately at startup), but the actual weight download happens on the node hosting the replica, not the driver. A thin head therefore never downloads model weights at all, and a worker only pulls what it's actually asked to run.

This means, per fleet: - Every node that can host a given model needs its own disk for that model's weights, and its own egress from HuggingFace (or wherever the weights live). - A shared NFS/EFS mount for the cache directory (MSHIP_CACHE_DIR) is an optional optimization — every node dedupes onto one copy — not a requirement. If you don't have shared storage, per-node caches work correctly on their own. - Local-path model: references (as opposed to a HuggingFace repo id) are resolved on whichever node actually hosts the replica — the file must exist at that path on every node that could host it, since there's no cross-node copying of a local reference.

MSHIP_STATE_STORE=redis:// is the multi-node recommendation

Without it, the effective config (this gateway's desired model set) and the deploy coordinator's routing registry live in a cluster-scoped Ray actor — they survive a redeploy or coordinator restart, but not the loss of the head/cluster itself. A redis:// store survives cluster loss too, so --reconcile with no --config on a fresh cluster (or a rejoining node) restores the real model set instead of coming back empty. See State store (MSHIP_STATE_STORE) for the full connection-URI reference — the head is otherwise a single point of failure for this state, same as it is for Ray's GCS itself.

Co-location: running more than one node per physical box

Co-location is a supported topology, not a footgun to avoid — the two patterns below are deliberate ways to pack more onto hardware you already have. What is still your responsibility: fencing which physical resources each container gets, so two containers on one box don't both believe they own the same hardware. See AGENTS.md's co-location note for the full fencing discipline (--gpus device=N, --node-memory + --shm-size, --cpuset-cpus + --node-num-cpus) — this page only covers the two topologies it unlocks. Reserving more GPUs than a container can actually see is refused at startup (not silently broken later); each node also logs every GPU it sees, by index, name, and UUID, at startup — check that log to confirm two co-located containers were actually handed distinct physical cards.

Head-farm: several cluster heads on one machine

One box can host the control plane for 3-4 independent modelship clusters, each a separate own-head container with its own distinct ports:

docker run -d --network=host --shm-size=8g \
  -v ./cluster-a/models.yaml:/modelship/config/models.yaml \
  -v ./cluster-a/cache:/.cache \
  ghcr.io/alez007/modelship:0.6.5 \
  --ray-port=6380 --openai-api-port=8000 --dashboard-port=8265

docker run -d --network=host --shm-size=8g \
  -v ./cluster-b/models.yaml:/modelship/config/models.yaml \
  -v ./cluster-b/cache:/.cache \
  ghcr.io/alez007/modelship:0.6.5 \
  --ray-port=6381 --openai-api-port=8001 --dashboard-port=8266

Each head needs a distinct --ray-port, --openai-api-port, --dashboard-port, and RAY_METRICS_EXPORT_PORT — see the port table above for what each one gates. Workers on other machines join whichever cluster they're meant to serve, by pointing --address at that head's GCS port.

One GPU, shared across two clusters

A single physical GPU can back worker containers in two different clusters at once — this is plain GPU sharing (the same idea as two vLLM processes each capped at gpu_memory_utilization=0.4), not a bookkeeping error, because each cluster's resource ledger is independent and has no visibility into the other's:

# Joins cluster A
docker run -d --network=host --gpus device=0 \
  ghcr.io/alez007/modelship:0.6.5-cuda \
  --address=<cluster-a-head>:6380 --node-num-gpus=1

# Joins cluster B — same physical GPU, different cluster
docker run -d --network=host --gpus device=0 \
  ghcr.io/alez007/modelship:0.6.5-cuda \
  --address=<cluster-b-head>:6380 --node-num-gpus=1

Ray does not arbitrate VRAM across independent clusters — that budget is yours to manage, the same way you'd size two co-resident models on one GPU within a single cluster (fractional num_gpus, gpu_memory_utilization, or llama_server's n_gpu_layers) so both sides' footprints actually fit together on the card.

See also

  • helm/modelship/README.md — the Kubernetes rung: same image variants and version-pinning rule, but autoscaling, self-healing pod scheduling, and (unlike this page's manual token setup) no Ray cluster-auth wiring yet.
  • development.md — the full CLI/env var reference table, image variants, and dev-container setup.